Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
J Headache Pain ; 23(1): 80, 2022 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-35820799

RESUMO

INTRODUCTION: Several functional neuroimaging studies on healthy controls and patients with migraine with aura have shown that the activation of functional networks during visual stimulation is not restricted to the striate system, but also includes several extrastriate networks. METHODS: Before and after 4 min of visual stimulation with a checkerboard pattern, we collected functional MRI in 21 migraine with aura (MwA) patients and 18 healthy subjects (HS). For each recording session, we identified independent resting-state networks in each group and correlated network connection strength changes with clinical disease features. RESULTS: Before visual stimulation, we found reduced connectivity between the default mode network and the left dorsal attention system (DAS) in MwA patients compared to HS. In HS, visual stimulation increases functional connectivity between the independent components of the bilateral DAS and the executive control network (ECN). In MwA, visual stimulation significantly improved functional connectivity between the independent component pairs salience network and DAS, and between DAS and ECN. The ECN Z-scores after visual stimulation were negatively related to the monthly frequency of aura. CONCLUSIONS: In individuals with MwA, 4 min of visual stimulation had stronger cognitive impact than in healthy people. A higher frequency of aura may lead to a diminished ability to obtain cognitive resources to cope with transitory but important events like aura-related focal neurological symptoms.


Assuntos
Epilepsia , Enxaqueca com Aura , Mapeamento Encefálico/métodos , Humanos , Imageamento por Ressonância Magnética/métodos , Estimulação Luminosa
2.
Phys Med ; 85: 98-106, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33991807

RESUMO

PURPOSE: The purpose of this multicenter phantom study was to exploit an innovative approach, based on an extensive acquisition protocol and unsupervised clustering analysis, in order to assess any potential bias in apparent diffusion coefficient (ADC) estimation due to different scanner characteristics. Moreover, we aimed at assessing, for the first time, any effect of acquisition plan/phase encoding direction on ADC estimation. METHODS: Water phantom acquisitions were carried out on 39 scanners. DWI acquisitions (b-value = 0-200-400-600-800-1000 s/mm2) with different acquisition plans (axial, coronal, sagittal) and phase encoding directions (anterior/posterior and right/left, for the axial acquisition plan), for 3 orthogonal diffusion weighting gradient directions, were performed. For each acquisition setup, ADC values were measured in-center and off-center (6 different positions), resulting in an entire dataset of 84 × 39 = 3276 ADC values. Spatial uniformity of ADC maps was assessed by means of the percentage difference between off-center and in-center ADC values (Δ). RESULTS: No significant dependence of in-center ADC values on acquisition plan/phase encoding direction was found. Ward unsupervised clustering analysis showed 3 distinct clusters of scanners and an association between Δ-values and manufacturer/model, whereas no association between Δ-values and maximum gradient strength, slew rate or static magnetic field strength was revealed. Several acquisition setups showed significant differences among groups, indicating the introduction of different biases in ADC estimation. CONCLUSIONS: Unsupervised clustering analysis of DWI data, obtained from several scanners using an extensive acquisition protocol, allows to reveal an association between measured ADC values and manufacturer/model of scanner, as well as to identify suboptimal DWI acquisition setups for accurate ADC estimation.


Assuntos
Imagem de Difusão por Ressonância Magnética , Análise por Conglomerados , Difusão , Imagens de Fantasmas , Reprodutibilidade dos Testes
3.
Neuroradiology ; 63(2): 235-242, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32918150

RESUMO

PURPOSE: Impaired olfactory function is one of the main features of Parkinson's disease. However, how peripheral olfactory structures are involved remains unclear. Using diffusion tensor imaging fiber tracking, we investigated for MRI microstructural changes in the parkinsonian peripheral olfactory system and particularly the olfactory tract, in order to seek a better understanding of the structural alternations underlying hyposmia in Parkinson's disease. METHODS: All patients were assessed utilizing by the Italian Olfactory Identification Test for olfactory function and the Unified Parkinson's Disease Rating Scale-III part as well as Hoehn and Yahr rating scale for motor disability. Imaging was performed on a 3 T Clinical MR scanner. MRI data pre-processing was carried out by DTIPrep, diffusion tensor imaging reconstruction, and fiber tracking using Diffusion Toolkit and tractography analysis by TrackVis. The following parameters were used for groupwise comparison: fractional anisotropy, mean diffusivity, radial diffusivity, axial diffusivity, and tract volume. RESULTS: Overall 23 patients with Parkinson's disease (mean age 63.6 ± 9.3 years, UPDRS-III 24.5 ± 12.3, H&Y 1.9 ± 0.5) and 18 controls (mean age 56.3 ± 13.7 years) were recruited. All patients had been diagnosed hyposmic. Diffusion tensor imaging analysis of the olfactory tract showed significant fractional anisotropy, and tract volume decreases for the Parkinson's disease group compared with controls (P < 0.05). Fractional anisotropy and age, in the control group, were significant for multiple correlations (r = - 0.36, P < 0.05, Spearman's rank correlation). CONCLUSIONS: Fiber tracking diffusion tensor imaging analysis of olfactory tract was feasible, and it could be helpful for characterizing hyposmia in Parkinson's disease.


Assuntos
Pessoas com Deficiência , Transtornos Motores , Bulbo Olfatório , Doença de Parkinson , Idoso , Anisotropia , Imagem de Tensor de Difusão , Humanos , Pessoa de Meia-Idade , Bulbo Olfatório/diagnóstico por imagem , Doença de Parkinson/diagnóstico por imagem
4.
J Alzheimers Dis ; 79(1): 163-175, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33252070

RESUMO

BACKGROUND: The cerebrospinal fluid (CSF) biomarkers amyloid-ß 1-42 (Aß42), total and phosphorylated tau (t-tau, p-tau) are increasingly used to assist in the clinical diagnosis of Alzheimer's disease (AD). However, CSF biomarker levels can be affected by confounding factors. OBJECTIVE: To investigate the association of white matter hyperintensities (WMHs) present in the brain with AD CSF biomarker levels. METHODS: We included CSF biomarker and magnetic resonance imaging (MRI) data of 172 subjects (52 controls, 72 mild cognitive impairment (MCI), and 48 AD patients) from 9 European Memory Clinics. A computer aided detection system for standardized automated segmentation of WMHs was used on MRI scans to determine WMH volumes. Association of WMH volume with AD CSF biomarkers was determined using linear regression analysis. RESULTS: A small, negative association of CSF Aß42, but not p-tau and t-tau, levels with WMH volume was observed in the AD (r2 = 0.084, p = 0.046), but not the MCI and control groups, which was slightly increased when including the distance of WMHs to the ventricles in the analysis (r2 = 0.105, p = 0.025). Three global patterns of WMH distribution, either with 1) a low, 2) a peak close to the ventricles, or 3) a high, broadly-distributed WMH volume could be observed in brains of subjects in each diagnostic group. CONCLUSION: Despite an association of WMH volume with CSF Aß42 levels in AD patients, the occurrence of WMHs is not accompanied by excess release of cellular proteins in the CSF, suggesting that WMHs are no major confounder for AD CSF biomarker assessment.


Assuntos
Doença de Alzheimer/líquido cefalorraquidiano , Peptídeos beta-Amiloides/líquido cefalorraquidiano , Disfunção Cognitiva/líquido cefalorraquidiano , Leucoencefalopatias/líquido cefalorraquidiano , Fragmentos de Peptídeos/líquido cefalorraquidiano , Proteínas tau/líquido cefalorraquidiano , Idoso , Doença de Alzheimer/diagnóstico , Disfunção Cognitiva/diagnóstico , Fatores de Confusão Epidemiológicos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Leucoencefalopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Fosforilação
5.
Brain Struct Funct ; 226(1): 137-150, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33231744

RESUMO

Accurate and reproducible automated segmentation of human hippocampal subfields is of interest to study their roles in cognitive functions and disease processes. Multispectral structural MRI methods have been proposed to improve automated hippocampal subfield segmentation accuracy, but the reproducibility in a multicentric setting is, to date, not well characterized. Here, we assessed test-retest reproducibility of FreeSurfer 6.0 hippocampal subfield segmentations using multispectral MRI analysis pipelines (22 healthy subjects scanned twice, a week apart, at four 3T MRI sites). The harmonized MRI protocol included two 3D-T1, a 3D-FLAIR, and a high-resolution 2D-T2. After within-session T1 averaging, subfield volumes were segmented using three pipelines with different multispectral data: two longitudinal ("long_T1s" and "long_T1s_FLAIR") and one cross-sectional ("long_T1s_FLAIR_crossT2"). Volume reproducibility was quantified in magnitude (reproducibility error-RE) and space (DICE coefficient). RE was lower in all hippocampal subfields, except for hippocampal fissure, using the longitudinal pipelines compared to long_T1s_FLAIR_crossT2 (average RE reduction of 0.4-3.6%). Similarly, the longitudinal pipelines showed a higher spatial reproducibility (1.1-7.8% of DICE improvement) in all hippocampal structures compared to long_T1s_FLAIR_crossT2. Moreover, long_T1s_FLAIR provided a small but significant RE improvement in comparison to long_T1s (p = 0.015), whereas no significant DICE differences were found. In addition, structures with volumes larger than 200 mm3 had better RE (1-2%) and DICE (0.7-0.95) than smaller structures. In summary, our study suggests that the most reproducible hippocampal subfield FreeSurfer segmentations are derived from a longitudinal pipeline using 3D-T1s and 3D-FLAIR. Adapting a longitudinal pipeline to include high-resolution 2D-T2 may lead to further improvements.


Assuntos
Envelhecimento , Hipocampo/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
6.
Magn Reson Imaging ; 76: 108-115, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33220450

RESUMO

Brain vascular damage accumulate in aging and often manifest as white matter hyperintensities (WMHs) on MRI. Despite increased interest in automated methods to segment WMHs, a gold standard has not been achieved and their longitudinal reproducibility has been poorly investigated. The aim of present work is to evaluate accuracy and reproducibility of two freely available segmentation algorithms. A harmonized MRI protocol was implemented in 3T-scanners across 13 European sites, each scanning five volunteers twice (test-retest) using 2D-FLAIR. Automated segmentation was performed using Lesion segmentation tool algorithms (LST): the Lesion growth algorithm (LGA) in SPM8 and 12 and the Lesion prediction algorithm (LPA). To assess reproducibility, we applied the LST longitudinal pipeline to the LGA and LPA outputs for both the test and retest scans. We evaluated volumetric and spatial accuracy comparing LGA and LPA with manual tracing, and for reproducibility the test versus retest. Median volume difference between automated WMH and manual segmentations (mL) was -0.22[IQR = 0.50] for LGA-SPM8, -0.12[0.57] for LGA-SPM12, -0.09[0.53] for LPA, while the spatial accuracy (Dice Coefficient) was 0.29[0.31], 0.33[0.26] and 0.41[0.23], respectively. The reproducibility analysis showed a median reproducibility error of 20%[IQR = 41] for LGA-SPM8, 14% [31] for LGA-SPM12 and 10% [27] with the LPA cross-sectional pipeline. Applying the LST longitudinal pipeline, the reproducibility errors were considerably reduced (LGA: 0%[IQR = 0], p < 0.001; LPA: 0% [3], p < 0.001) compared to those derived using the cross-sectional algorithms. The DC using the longitudinal pipeline was excellent (median = 1) for LGA [IQR = 0] and LPA [0.02]. LST algorithms showed moderate accuracy and good reproducibility. Therefore, it can be used as a reliable cross-sectional and longitudinal tool in multi-site studies.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Substância Branca/diagnóstico por imagem , Adulto , Envelhecimento , Algoritmos , Automação , Estudos Transversais , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Substância Branca/patologia
7.
Phys Med ; 78: 150-155, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33035926

RESUMO

PURPOSE: [18F]Fluoromethylcholine ([18F]FMCH) is a radiopharmaceutical used in positron emission tomography (PET) imaging for the study of prostate, breast, and brain tumors. It is usually synthesized in cyclotron facilities where 18F is produced by proton irradiation of [18O]H2O through 18O(p,n)18F reaction. Due to the activation of target materials, the bombardment causes unwanted radionuclidic impurities in [18O]H2O, that need to be removed during the radiopharmaceutical synthesis. Thus, the aim of this study is to quantify the radionuclide impurities in the 18F production process and in the synthesized [18F]FMCH, demonstrating the radionuclidic purity of this radiopharmaceutical. METHODS: Long-lived radionuclide impurities were experimentally assessed using high-resolution gamma and liquid scintillation spectrometries, while short-lived impurities were monitored analyzing the decay curve of the irradiated [18O]H2O with an activity calibrator. As spectrometric radionuclide library, a Geant4 Monte Carlo simulation of the 18F-target assembly was previously performed. RESULTS: 3H, 52,54Mn, 56,57,58Co, 95m,96Tc, 109Cd, and 184Re were found in the irradiated [18O]H2O, but no radionuclide was found in the non-irradiated [18O]H2O neither in the final [18F]FMCH solution with an activity concentration greater than the minimum detectable activity concentration. A total impurity activity <6.2 kBq was measured in the irradiated [18O]H2O, whereas a [18F]FMCH radionuclide purity >99.9999998% was estimated. Finally, the decay curve of the irradiated [18O]H2O revealed a very low maximum of 13N activity (<0.03% of 18F) even immediately after the end of bombardment. CONCLUSIONS: This study demonstrated the radionuclidic purity of [18F]FMCH according to the EU Pharmacopeia.


Assuntos
Radioisótopos , Compostos Radiofarmacêuticos , Colina/análogos & derivados , Ciclotrons , Tomografia por Emissão de Pósitrons
8.
J Pers Med ; 10(3)2020 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-32635476

RESUMO

Radionecrosis (RN) is the most important side effect after stereotactic radiotherapy (SRT) for brain metastases, with a reported incidence ranging from 3% to 24%. To date, there are no unanimously accepted criteria for iconographic diagnosis of RN, as well as no definitive dose-constraints correlated with the onset of this late effect. We reviewed the current literature and gave an overview report on imaging options for the diagnosis of RN and on dosimetric parameters correlated with the onset of RN. We performed a PubMed literature search according to the preferred reporting items and meta-analysis (PRISMA) guidelines, and identified articles published within the last ten years, up to 31 December 2019. When analyzing data on diagnostic tools, perfusion magnetic resonance imaging (MRI) seems to be very useful allowing evaluation of the blood flow in the lesion using the relative cerebral blood volume (rCBV) and blood vessel integrity using relative peak weight (rPH). It is necessary to combine morphological with functional imaging in order to match information about lesion morphology, metabolism and blood-flow. Eventually, serial imaging follow-up is needed. Regarding dosimetric parameters, in radiosurgery (SRS) V12 < 8 cm3 and V10 < 10.5 cm3 of normal brain are the most reliable prognostic factors, whereas in hypo-fractionated stereotactic radiotherapy (HSRT) V18 and V21 are considered the main predictive independent risk factors of RN.

9.
Neuroimage ; 218: 116932, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32416226

RESUMO

BACKGROUND: The amygdala and the hippocampus are two limbic structures that play a critical role in cognition and behavior, however their manual segmentation and that of their smaller nuclei/subfields in multicenter datasets is time consuming and difficult due to the low contrast of standard MRI. Here, we assessed the reliability of the automated segmentation of amygdalar nuclei and hippocampal subfields across sites and vendors using FreeSurfer in two independent cohorts of older and younger healthy adults. METHODS: Sixty-five healthy older (cohort 1) and 68 younger subjects (cohort 2), from the PharmaCog and CoRR consortia, underwent repeated 3D-T1 MRI (interval 1-90 days). Segmentation was performed using FreeSurfer v6.0. Reliability was assessed using volume reproducibility error (ε) and spatial overlapping coefficient (DICE) between test and retest session. RESULTS: Significant MRI site and vendor effects (p â€‹< â€‹.05) were found in a few subfields/nuclei for the ε, while extensive effects were found for the DICE score of most subfields/nuclei. Reliability was strongly influenced by volume, as ε correlated negatively and DICE correlated positively with volume size of structures (absolute value of Spearman's r correlations >0.43, p â€‹< â€‹1.39E-36). In particular, volumes larger than 200 â€‹mm3 (for amygdalar nuclei) and 300 â€‹mm3 (for hippocampal subfields, except for molecular layer) had the best test-retest reproducibility (ε â€‹< â€‹5% and DICE â€‹> â€‹0.80). CONCLUSION: Our results support the use of volumetric measures of larger amygdalar nuclei and hippocampal subfields in multisite MRI studies. These measures could be useful for disease tracking and assessment of efficacy in drug trials.


Assuntos
Tonsila do Cerebelo/anatomia & histologia , Hipocampo/anatomia & histologia , Processamento de Imagem Assistida por Computador/normas , Neuroimagem/normas , Software , Adulto , Idoso , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Neuroimagem/métodos , Reprodutibilidade dos Testes
10.
Phys Med ; 64: 29-32, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31515031

RESUMO

PURPOSE: Individual dosimetry allows to quantify doses from ionizing radiation of exposed workers. Scientific and epidemiological evidences highlight the need for adequate measures for a greater protection of the eye and a reduction in annual doses. ICRP Publication 103, illustrating the operational dose quantity Hp(d) for the individual monitoring, proposes a depth d = 3 mm for eye lens monitoring, indicating that even the Hp(0.07) can be used. In this study, it was investigated if there are differences in the evaluation of the equivalent dose to eye lens (Hlens) using Hp(3) or Hp(0.07). MATERIALS AND METHODS: A slab phantom calibration was performed by an Accredited Calibration Laboratory in terms of Hp(3) and Hp(0.07) using ext-rad TLD-100 (LiF:Mg,Ti) dosimeters. Hp(0.07) and Hp(3) were measured for 26 exposed workers to assess Hlens. The measuring took place monthly in 2017 to obtain both semestral and annual doses. RESULTS: Hlens(0.07) was always smaller than Hlens(3). However, the differences were not statistically significant (Mann-Whitney test, p > 0.05) for both semestral and annual doses. The percentage differences were 7 ±â€¯3%, 6 ±â€¯3% and 7 ±â€¯2% for I semester, II semester and whole year, respectively. The mean underestimation index <10%, intra-class correlation coefficient >0.99, coefficient of variation <3% and the excellent correlation (R2 ≈ 0.999) for both semestral and annual doses highlighted that Hp(0.07) can be used to evaluate Hlens instead of Hp(3). CONCLUSIONS: No statistical evidence was found that the use of Hp(0.07) underestimates the equivalent dose to eye lens obtained through Hp(3).


Assuntos
Cristalino/efeitos da radiação , Doses de Radiação
11.
Neurobiol Aging ; 80: 91-98, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31103636

RESUMO

Brain iron load is one of the main neuropathologic hallmarks of Parkinson's disease (PD). Previous studies indicated that iron in the substantia nigra (SN) is related to disease duration and motor impairment. We explore, through a cross-sectional study, the association between brain iron distribution, evaluated by T2*-weighted magnetic resonance imaging (T2*), and clinical features in a cohort of patients with PD. Thirty-two patients with PD, compared with 10 control subjects, were evaluated for motor and cognitive features (attention and working memory, executive functions, language, memory, and visuospatial function). They underwent a magnetic resonance imaging protocol including T2* analysis of specific brain regions of interest to measure iron load compared with healthy control subjects. We found that iron content of the SN correlated positively with both disease duration and Unified Parkinson's Disease Rating Scale III off score. Montreal Cognitive Assessment, Spatial Span, and Graded Naming Test scores were inversely associated with iron load of the SN, whereas Wechsler Adult Intelligence Scale-IV Similarities score showed an inverse relationship with iron content in all the regions of interest examined. Our findings suggest a relationship between topographic brain iron distribution and cognitive domain impairment.


Assuntos
Encéfalo/diagnóstico por imagem , Cognição , Disfunção Cognitiva/etiologia , Imagem de Difusão por Ressonância Magnética , Atividade Motora , Transtornos Motores/etiologia , Doença de Parkinson/diagnóstico por imagem , Doença de Parkinson/psicologia , Encéfalo/metabolismo , Disfunção Cognitiva/patologia , Feminino , Humanos , Ferro/metabolismo , Masculino , Pessoa de Meia-Idade , Transtornos Motores/patologia , Doença de Parkinson/complicações , Doença de Parkinson/fisiopatologia
12.
Phys Med ; 54: 49-55, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30337010

RESUMO

PURPOSE: The aim of this study was to propose and validate across various clinical scanner systems a straightforward multiparametric quality assurance procedure for proton magnetic resonance spectroscopy (MRS). METHODS: Eighteen clinical 1.5 T and 3 T scanner systems for MRS, from 16 centres and 3 different manufacturers, were enrolled in the study. A standard spherical water phantom was employed by all centres. The acquisition protocol included 3 sets of single (isotropic) voxel (size 20 mm) PRESS acquisitions with unsuppressed water signal and acquisition voxel position at isocenter as well as off-center, repeated 4/5 times within approximately 2 months. Water peak linewidth (LW) and area under the water peak (AP) were estimated. RESULTS: LW values [mean (standard deviation)] were 1.4 (1.0) Hz and 0.8 (0.3) Hz for 3 T and 1.5 T scanners, respectively. The mean (standard deviation) (across all scanners) coefficient of variation of LW and AP for different spatial positions of acquisition voxel were 43% (20%) and 11% (11%), respectively. The mean (standard deviation) phantom T2values were 1145 (50) ms and 1010 (95) ms for 1.5 T and 3 T scanners, respectively. The mean (standard deviation) (across all scanners) coefficients of variation for repeated measurements of LW, AP and T2 were 25% (20%), 10% (14%) and 5% (2%), respectively. CONCLUSIONS: We proposed a straightforward multiparametric and not time consuming quality control protocol for MRS, which can be included in routine and periodic quality assurance procedures. The protocol has been validated and proven to be feasible in a multicentre comparison study of a fairly large number of clinical 1.5 T and 3 T scanner systems.


Assuntos
Espectroscopia de Prótons por Ressonância Magnética/normas , Imagens de Fantasmas , Controle de Qualidade
13.
Phys Med ; 55: 135-141, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30342982

RESUMO

PURPOSE: To propose an MRI quality assurance procedure that can be used for routine controls and multi-centre comparison of different MR-scanners for quantitative diffusion-weighted imaging (DWI). MATERIALS AND METHODS: 44 MR-scanners with different field strengths (1 T, 1.5 T and 3 T) were included in the study. DWI acquisitions (b-value range 0-1000 s/mm2), with three different orthogonal diffusion gradient directions, were performed for each MR-scanner. All DWI acquisitions were performed by using a standard spherical plastic doped water phantom. Phantom solution ADC value and its dependence with temperature was measured using a DOSY sequence on a 600 MHz NMR spectrometer. Apparent diffusion coefficient (ADC) along each diffusion gradient direction and mean ADC were estimated, both at magnet isocentre and in six different position 50 mm away from isocentre, along positive and negative AP, RL and HF directions. RESULTS: A good agreement was found between the nominal and measured mean ADC at isocentre: more than 90% of mean ADC measurements were within 5% from the nominal value, and the highest deviation was 11.3%. Away from isocentre, the effect of the diffusion gradient direction on ADC estimation was larger than 5% in 47% of included scanners and a spatial non uniformity larger than 5% was reported in 13% of centres. CONCLUSION: ADC accuracy and spatial uniformity can vary appreciably depending on MR scanner model, sequence implementation (i.e. gradient diffusion direction) and hardware characteristics. The DWI quality assurance protocol proposed in this study can be employed in order to assess the accuracy and spatial uniformity of estimated ADC values, in single- as well as multi-centre studies.


Assuntos
Imagem de Difusão por Ressonância Magnética/instrumentação , Difusão , Imagens de Fantasmas , Controle de Qualidade
14.
Front Aging Neurosci ; 10: 439, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30705627

RESUMO

Background/Aims: We aimed to assess the association between in volumetric measures of hippocampal sub-regions - in healthy older controls (HC), subjects with mild cognitive impairment (MCI) and AD- with circulating levels of IL-4. Methods: From AddNeuroMed Project 113 HC, 101 stable MCI (sMCI), 22 converter MCI (cMCI) and 119 AD were included. Hippocampal subfield volumes were analyzed using Freesurfer 6.0.0 on high-resolution sagittal 3D-T1W MP-RAGE acquisitions. Plasmatic IL-4 was measured using ELISA assay. Results: IL-4 was found to be (a) positively associate with left subiculum volume (ß = 0.226, p = 0.037) in sMCI and (b) negatively associate with left subiculum volume (ß = -0.253, p = 0.011) and left presubiculum volume (ß = -0.257, p = 0.011) in AD. Conclusion: Our results indicate a potential neuroprotective effect of IL-4 on the areas of the hippocampus more vulnerable to aging and neurodegeneration.

15.
J Alzheimers Dis ; 56(2): 543-555, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28059783

RESUMO

Cerebrospinal fluid (CSF) biomarkers may support the diagnosis of Alzheimer's disease (AD). We studied if the diagnostic power of AD CSF biomarker concentrations, i.e., Aß42, total tau (t-tau), and phosphorylated tau (p-tau), is affected by differences in lateral ventricular volume (VV), using CSF biomarker data and magnetic resonance imaging (MRI) scans of 730 subjects, from 13 European Memory Clinics. We developed a Matlab-algorithm for standardized automated segmentation analysis of T1 weighted MRI scans in SPM8 for determining VV, and computed its ratio with total intracranial volume (TIV) as proxy for total CSF volume. The diagnostic power of CSF biomarkers (and their combination), either corrected for VV/TIV ratio or not, was determined by ROC analysis. CSF Aß42 levels inversely correlated to VV/TIV in the whole study population (Aß42: r = -0.28; p < 0.0001). For CSF t-tau and p-tau, this association only reached statistical significance in the combined MCI and AD group (t-tau: r = -0.15; p-tau: r = -0.13; both p < 0.01). Correction for differences in VV/TIV improved the differentiation of AD versus controls based on CSF Aß42 alone (AUC: 0.75 versus 0.81) or in combination with t-tau (AUC: 0.81 versus 0.91). In conclusion, differences in VV may be an important confounder in interpreting CSF Aß42 levels.


Assuntos
Doença de Alzheimer/líquido cefalorraquidiano , Doença de Alzheimer/diagnóstico por imagem , Ventrículos Cerebrais/diagnóstico por imagem , Disfunção Cognitiva/líquido cefalorraquidiano , Disfunção Cognitiva/diagnóstico por imagem , Idoso , Algoritmos , Peptídeos beta-Amiloides/líquido cefalorraquidiano , Área Sob a Curva , Atrofia , Biomarcadores/líquido cefalorraquidiano , Feminino , Hipocampo/diagnóstico por imagem , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Reconhecimento Automatizado de Padrão , Fragmentos de Peptídeos/líquido cefalorraquidiano , Curva ROC , Proteínas tau/líquido cefalorraquidiano
16.
Hum Brain Mapp ; 38(1): 12-26, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27519630

RESUMO

Free water elimination (FWE) in brain diffusion MRI has been shown to improve tissue specificity in human white matter characterization both in health and in disease. Relative to the classical diffusion tensor imaging (DTI) model, FWE is also expected to increase sensitivity to microstructural changes in longitudinal studies. However, it is not clear if these two models differ in their test-retest reproducibility. This study compares a bi-tensor model for FWE with DTI by extending a previous longitudinal-reproducibility 3T multisite study (10 sites, 7 different scanner models) of 50 healthy elderly participants (55-80 years old) scanned in two sessions at least 1 week apart. We computed the reproducibility of commonly used DTI metrics (FA: fractional anisotropy, MD: mean diffusivity, RD: radial diffusivity, and AXD: axial diffusivity), derived either using a DTI model or a FWE model. The DTI metrics were evaluated over 48 white-matter regions of the JHU-ICBM-DTI-81 white-matter labels atlas, and reproducibility errors were assessed. We found that relative to the DTI model, FWE significantly reduced reproducibility errors in most areas tested. In particular, for the FA and MD metrics, there was an average reduction of approximately 1% in the reproducibility error. The reproducibility scores did not significantly differ across sites. This study shows that FWE improves sensitivity and is thus promising for clinical applications, with the potential to identify more subtle changes. The increased reproducibility allows for smaller sample size or shorter trials in studies evaluating biomarkers of disease progression or treatment effects. Hum Brain Mapp 38:12-26, 2017. © 2016 Wiley Periodicals, Inc.


Assuntos
Envelhecimento , Encéfalo/diagnóstico por imagem , Imagem de Tensor de Difusão , Água/metabolismo , Idoso , Idoso de 80 Anos ou mais , Anisotropia , Feminino , Voluntários Saudáveis , Humanos , Imageamento Tridimensional , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Substância Branca/diagnóstico por imagem
17.
Hum Brain Mapp ; 37(6): 2114-32, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26990928

RESUMO

Understanding how to reduce the influence of physiological noise in resting state fMRI data is important for the interpretation of functional brain connectivity. Limited data is currently available to assess the performance of physiological noise correction techniques, in particular when evaluating longitudinal changes in the default mode network (DMN) of healthy elderly participants. In this 3T harmonized multisite fMRI study, we investigated how different retrospective physiological noise correction (rPNC) methods influence the within-site test-retest reliability and the across-site reproducibility consistency of DMN-derived measurements across 13 MRI sites. Elderly participants were scanned twice at least a week apart (five participants per site). The rPNC methods were: none (NPC), Tissue-based regression, PESTICA and FSL-FIX. The DMN at the single subject level was robustly identified using ICA methods in all rPNC conditions. The methods significantly affected the mean z-scores and, albeit less markedly, the cluster-size in the DMN; in particular, FSL-FIX tended to increase the DMN z-scores compared to others. Within-site test-retest reliability was consistent across sites, with no differences across rPNC methods. The absolute percent errors were in the range of 5-11% for DMN z-scores and cluster-size reliability. DMN pattern overlap was in the range 60-65%. In particular, no rPNC method showed a significant reliability improvement relative to NPC. However, FSL-FIX and Tissue-based physiological correction methods showed both similar and significant improvements of reproducibility consistency across the consortium (ICC = 0.67) for the DMN z-scores relative to NPC. Overall these findings support the use of rPNC methods like tissue-based or FSL-FIX to characterize multisite longitudinal changes of intrinsic functional connectivity. Hum Brain Mapp 37:2114-2132, 2016. © 2016 Wiley Periodicals, Inc.


Assuntos
Mapeamento Encefálico , Encéfalo/fisiologia , Imageamento por Ressonância Magnética , Idoso , Mapeamento Encefálico/métodos , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Vias Neurais/fisiologia , Análise de Regressão , Reprodutibilidade dos Testes , Descanso , Estudos Retrospectivos
18.
Neuroimage ; 124(Pt A): 442-454, 2016 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-26163799

RESUMO

To date, limited data are available regarding the inter-site consistency of test-retest reproducibility of functional connectivity measurements, in particular with regard to integrity of the Default Mode Network (DMN) in elderly participants. We implemented a harmonized resting-state fMRI protocol on 13 clinical scanners at 3.0T using vendor-provided sequences. Each site scanned a group of 5 healthy elderly participants twice, at least a week apart. We evaluated inter-site differences and test-retest reproducibility of both temporal signal-to-noise ratio (tSNR) and functional connectivity measurements derived from: i) seed-based analysis (SBA) with seed in the posterior cingulate cortex (PCC), ii) group independent component analysis (ICA) separately for each site (site ICA), and iii) consortium ICA, with group ICA across the whole consortium. Despite protocol harmonization, significant and quantitatively important inter-site differences remained in the tSNR of resting-state fMRI data; these were plausibly driven by hardware and pulse sequence differences across scanners which could not be harmonized. Nevertheless, the tSNR test-retest reproducibility in the consortium was high (ICC=0.81). The DMN was consistently extracted across all sites and analysis methods. While significant inter-site differences in connectivity scores were found, there were no differences in the associated test-retest error. Overall, ICA measurements were more reliable than PCC-SBA, with site ICA showing higher reproducibility than consortium ICA. Across the DMN nodes, the PCC yielded the most reliable measurements (≈4% test-retest error, ICC=0.85), the medial frontal cortex the least reliable (≈12%, ICC=0.82) and the lateral parietal cortices were in between (site ICA). Altogether these findings support usage of harmonized multisite studies of resting-state functional connectivity to characterize longitudinal effects in studies that assess disease progression and treatment response.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/fisiologia , Giro do Cíngulo/fisiologia , Imageamento por Ressonância Magnética/métodos , Idoso , Idoso de 80 Anos ou mais , Artefatos , Interpretação Estatística de Dados , Humanos , Estudos Longitudinais , Pessoa de Meia-Idade , Vias Neurais/fisiologia , Reprodutibilidade dos Testes , Razão Sinal-Ruído
19.
J Magn Reson Imaging ; 43(1): 213-9, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26013043

RESUMO

PURPOSE: To propose a magnetic resonance imaging (MRI) quality assurance procedure that can be used for multicenter comparison of different MR scanners for quantitative diffusion-weighted imaging (DWI). MATERIALS AND METHODS: Twenty-six centers (35 MR scanners with field strengths: 1T, 1.5T, and 3T) were enrolled in the study. Two different DWI acquisition series (b-value ranges 0-1000 and 0-3000 s/mm(2) , respectively) were performed for each MR scanner. All DWI acquisitions were performed by using a cylindrical doped water phantom. Mean apparent diffusion coefficient (ADC) values as well as ADC values along each of the three main orthogonal directions of the diffusion gradients (x, y, and z) were calculated. Short-term repeatability of ADC measurement was evaluated for 26 MR scanners. RESULTS: A good agreement was found between the nominal and measured mean ADC over all the centers. More than 80% of mean ADC measurements were within 5% from the nominal value, and the highest deviation and overall standard deviation were 9.3% and 3.5%, respectively. Short-term repeatability of ADC measurement was found <2.5% for all MR scanners. CONCLUSION: A specific and widely accepted protocol for quality controls in DWI is still lacking. The DWI quality assurance protocol proposed in this study can be applied in order to assess the reliability of DWI-derived indices before tackling single- as well as multicenter studies.


Assuntos
Imagem de Difusão por Ressonância Magnética/instrumentação , Imagem de Difusão por Ressonância Magnética/normas , Interpretação de Imagem Assistida por Computador/instrumentação , Interpretação de Imagem Assistida por Computador/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Imagem de Difusão por Ressonância Magnética/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Interpretação de Imagem Assistida por Computador/métodos , Itália , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Hum Brain Mapp ; 36(9): 3516-27, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26043939

RESUMO

Recently, there has been an increased interest in the use of automatically segmented subfields of the human hippocampal formation derived from magnetic resonance imaging (MRI). However, little is known about the test-retest reproducibility of such measures, particularly in the context of multisite studies. Here, we report the reproducibility of automated Freesurfer hippocampal subfields segmentations in 65 healthy elderly enrolled in a consortium of 13 3T MRI sites (five subjects per site). Participants were scanned in two sessions (test and retest) at least one week apart. Each session included two anatomical 3D T1 MRI acquisitions harmonized in the consortium. We evaluated the test-retest reproducibility of subfields segmentation (i) to assess the effects of averaging two within-session T1 images and (ii) to compare subfields with whole hippocampus volume and spatial reliability. We found that within-session averaging of two T1 images significantly improved the reproducibility of all hippocampal subfields but not that of the whole hippocampus. Volumetric and spatial reproducibility across MRI sites were very good for the whole hippocampus, CA2-3, CA4-dentate gyrus (DG), subiculum (reproducibility error∼2% and DICE > 0.90), good for CA1 and presubiculum (reproducibility error ∼ 5% and DICE ∼ 0.90), and poorer for fimbria and hippocampal fissure (reproducibility error ∼ 15% and DICE < 0.80). Spearman's correlations confirmed that test-retest reproducibility improved with volume size. Despite considerable differences of MRI scanner configurations, we found consistent hippocampal subfields volumes estimation. CA2-3, CA4-DG, and sub-CA1 (subiculum, presubiculum, and CA1 pooled together) gave test-retest reproducibility similar to the whole hippocampus. Our findings suggest that the larger hippocampal subfields volume may be reliable longitudinal markers in multisite studies.


Assuntos
Envelhecimento/patologia , Hipocampo/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Idoso , Europa (Continente) , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Reprodutibilidade dos Testes , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...